10 Troubleshooting
In the following chapters, support for issues with the Draco MV is provided. Please ensure before
operating the Draco MV that the Draco MV is connected over a peer-to-peer connection.
If using the Draco MV with KVM extenders or a KVM matrix switch, please refer to the relevant
manuals for assistance if there is an issue
10.1 Network Error
Diagnosis
Possible reason
Measure
Network settings are
not assumed after
editing.
Restart of the Draco MV
not yet completed.
Restart the Draco MV.
10.2 Failure at the Draco MV
Diagnosis
Possible reason
Measure
Opening the OSD not
possible
Wrong ‘Hot Key’
Reset ‘Hot Key’ if necessary (see
10.3 Failure at the USB-HID Port
Diagnosis
Possible reason
Measure
Caps Lock
and
Scroll Lock
LEDs on
the keyboard are
flashing
Keyboard in command
mode
Press
<Esc>
key to leave the command
mode
USB device without
function
No USB-HID device
recognized
Connect a USB-HID device.
USB-HID device is not
supported
Check the compatibility.
Contact your dealer if necessary.
10.4 Video Interference
Diagnosis
Possible reason
Measure
Incorrect video
display
Cable connection disturbed
Check the integrity of the video cable.
Reboot of source (computer, CPU).