
ifm
System Manual
ecomat
mobile
PDM360NG (CR1080, CR1081, CR9042) Target V01
2011-07-28
LED, buzzer, visualisation
Edit input fields in the visualisation
407
Parameters of the outputs
3339
Parameter
Data type
Description
INPUT_ACTIV BOOL
current
visualisation
number
FIELDCOUNTER
BYTE
number of selected input field
VALUE_FIELD1 REAL
... REAL
VALUE_FIELD6 REAL
external input value, is only adopted with the 2nd rising edge of
ENTER
Internal parameters
3340
Name
Data type
Description
FIELD1 REAL
... REAL
FIELD6 REAL
Sets the focus for the selected input field.
Any visualisation object can be used as a focus. The variable FIELDx must be
assigned to this object in the visualisation. If the input is active, FIELDx is
pulsed.
COLOR_FIELD1 REAL
... REAL
COLOR_FIELD6 REAL
Sets the alarm colour of the input object (only PDM color).
The variable must be assigned in the visualisation.
VALUE_FIELD_1 REAL
... REAL
VALUE_FIELD_6 REAL
Internal input value which is immediately visible during the input and
transferred to VALUE_FIELDx on the second rising edge of ENTER.
The variable must be assigned in the visualisation.