![background image](http://html1.mh-extra.com/html/ifm/ecomatmobile-ecomat100-cr1080/ecomatmobile-ecomat100-cr1080_system-manual_620622239.webp)
ifm
System Manual
ecomat
mobile
PDM360NG (CR1080, CR1081, CR9042) Target V01
2011-07-28
CAN in the PDM360
CAN units acc. to SAE J1939
239
Parameters of the outputs
7744
Parameter
Data type
Description
SA BYTE
S
ource
a
ddress of the transmitter
PRIO
BYTE
message priority (0…7)
LEN
WORD
number of the bytes received
permissible values = 0000 0000...0000 06F9
16
= 0...1 785
10
DATA
ARRAY [0...1784] OF BYTE
data to be sent (1...1785 bytes)
RESULT
BYTE
feedback of the function block
(possible messages
following table)
Possibly values for RESULT:
Value
dec | hex
Description
000
00
function block is not active
001
01
FB execution completed without error – data is valid
005
05
FB is active – no data received yet
242
F2
Error: setting is not possible