ifm
System Manual
ecomat
mobile
PDM360NG (CR1080, CR1081, CR9042) Target V01
2011-07-28
CAN in the PDM360
CAN units acc. to SAE J1939
213
J1939_ENABLE
7641
Unit type = function block (FB)
Contained in the library:
ifm_J1939_NT_Vxxyyzz.LIB
Available for the following devices:
- BasicController: CR040n
- BasicDisplay: CR0451
- PDM360NG: CR108n, CR9042
Symbol in CoDeSys:
Description
7642
For initialisation of the J1939 stack, J1939_ENABLE is set to TRUE=1.
> This FB also causes booting of the soft I/Os of the CFG file.
> A different baud rate is only adopted if CAN_ENABLE has not been activated before.
ACE =
A
ddress
C
laiming
E
nable:
If an ifm controller communicates with only one engine controller via J1939:
set ACE = FALSE.
If however several engine controllers are working on the same bus:
set ACE = TRUE.
In this case the engine controllers must support the address claiming!
Otherwise you will risk an overlapping of addresses with subsequent system failure.