Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077
16
4.5 Other installation types
Permissible installation types:
(→ 4.3 Panel mounting / control cabinet installation)
(→ 4.4 Surface mounting with RAM
All other installation types are in the sole responsibility of the system
creator�
5 Electrical connection
►
Disconnect the machine from the mains supply before installation; if
necessary, also disconnect any independently supplied input / output
load circuits�
This also applies to the M12 connectors�
►
Observe the national and international regulations for the installation of
electrical equipment�
Accessible surfaces of the device are insulated from the circuits with basic
insulation according to IEC 61010-1 (secondary circuit with max. 32 V DC,
supplied from the mains circuit up to 300 V of overvoltage category II).
GND of the supply is connected via EMC suppression capacitors on the shield
connection (metal housing) of the device.
External wiring must ensure the required separation from other circuits�
5.1 Wiring
Wiring
The connections or wires may only be supplied with the signals indicated in
the technical data or on the device label�
Seal the individual cores of unconnected connector pins�