Process and dialogue module ecomatDisplay CR1074, CR1075, CR1076, CR1077
14
NOTE!
Contact corrosion between the mounting screws and the housing�
> Damage to the device
►
Do not use copper or nickel-plated materials for the bolting
elements�
►
Use zinc-plated screws�
►
In very corrosive environments such as extremely salty air, use
screws with surface finishing on a zinc/nickel basis with thick-film
passivation and sealing�
1
2
3
4
5
6
7
A
Mounting principle
1: M5 hexagon nuts
2: Fixing profile
3: Panel cut-out
4: Spacer
5: Damping strips
6: Set screws
7: Dialogue module
Installation depth A = device depth (approx. 53 mm)
Installation depth with the attached connector:
approx� 77 mm