ENGLISH
OUTPUT MODULE
CR2011
PAGE
27
Dimensions
Electrical connection
To protect the whole system (wiring and output module) the individual elec-
tric circuits must be protected with max. 16A.
152
11
18
60
107
39
4,5
36
1
2
3
4
5
6
7
8
M12x1
LED
core colour
potential
Operating voltage
red
10 ... 30 V DC
black
GND
CAN interface
white
CAN_H
blue
CAN_L
green
CAN_GND
M12 connector PIN
connection
4
switching output L+
3
external voltage -
5
n. c.
1
3
4
2
5
M12 connector PIN
connection
4
switching output L+
2
(measuring resistor integrated)
external voltage -
5
n. c.
1
3
4
2
5
Wiring
Outputs without current monitoring
Outputs with current monitoring