7.5
DISPLACEMENT DEVICE USE
WARNING - CAUTION:
before carrying out this intervention, disconnect the bar feeder power supply.
During the intervention take extreme care so as not to damage the connection
cables.
Perform this operation following the
instructions given hereunder:
- Disconnect the bar feeder-lathe
fastening unit (if installed).
- Remove the protection guard (D).
- Remove the safety screw (E).
- Lower the lever (A) until it releases,
then rotate it forward.
- Move the bar feeder until the bar stop
(B) exceeds the stop (C).
- Carry out all lathe tooling and/or
maintenance operations required.
- Lift the bar stop (B) and put the bar
feeder again in its initial position.
- Put the lever (A) in position.
B
C
A
E
D