CAPACITIVE SENSOR - REPLACEMENT
- Replace the capacitive sensor.
- Position a 4 mm ø bar on the lifted loading
levers.
- Adjust the sensitivity of the sensor by setting it
at the minimum value.
- Gradually increase the sensibility until the
luminous led (A) switches on.
- Said led must switch off when the bar is
removed.
9.6
GUIDE CONTROL SENSORS - REPLACEMENT
Guide closing sensors
- Replace the sensors (A).
- Adjust their position on the diameter Ø (B) of
the rod, not on diameter Ø (C).
CAUTION:
If the position of the sensors were
adjusted on diameter ø (C), they would
be cut during rod extension.