7 - BAR FEEDER MAINTENANCE
SIR 52 MS52 P/F
EN
7 - Pag. 17 / 20
7.2.20 Air filter unit - Check
FILTER A
• Make sure that cup (B) is not full of condensate.
If need be, bleed the condensate by valve
(C).Make sure that cup (B) is not full of
condensate. If need be, bleed the condensate by
valve (C).
PRESSURE SWITCH
• The lubricator is equipped with a control
pressure switch, set to a pressure of 4.5 bars.
• To adjust the pressure switch, proceed as
follows:
- remove the pressure gauge protecting glass;
- turn the adjusting screw (G) anticlockwise
(+) to increase pressure or clockwise (-) to
lower it;
- after this operation, replace the pressure gauge protecting glass.
CAUTION:
should the pressure switch needle point a Pressure=0, do not absolutely turn
the adjusting screw (H) clockwise (-), for this will cause pressure switch
breakage.
Summary of Contents for SIR52 MS52 F
Page 2: ......
Page 4: ......
Page 6: ......
Page 20: ...EN 2 TECHNICAL INFORMATION SIR 52 MS52 P F 2 Pag 10 14 2 6 TECHNICAL INFORMATION ...
Page 24: ...EN 2 TECHNICAL INFORMATION SIR 52 MS52 P F 2 Pag 14 14 ...
Page 50: ...EN 4 HANDLING AND INSTALLATION SIR 52 MS52 P F 4 Pag 22 22 ...
Page 72: ...EN 5 ADJUSTMENTS AND SETTING UP SIR 52 MS52 P F 5 Pag 22 22 ...
Page 102: ...EN 6 USE AND OPERATION SIR 52 MS52 P F 6 Pag 30 30 ...
Page 148: ...EN 9 PART REPLACEMENT SIR 52 MS52 P F 9 Pag 16 16 ...
Page 174: ...EN 11 GUIDE CHANNELS BAR PUSHER REVOLVING TIPS SIR 52 MS52 P F 11 Pag 6 6 ...
Page 185: ...12 GRIPPERS SIR 52 MS52 P F EN 12 Pag 11 34 ...
Page 203: ...12 GRIPPERS SIR 52 MS52 P F EN 12 Pag 29 34 ...
Page 212: ...EN 13 LIST OF AFTER SALES CENTERS SIR 52 MS52 P F 13 Pag 4 4 ...