4 - HANDLING AND INSTALLATION
SIR-52-P/F
4 - Pag. 18 / 22
In case of transport, displacements or
further installations of the bar feeder, a
plug (E) is supplied, to be introduced into
the oil collecting tank to prevent the
lubricating oil from leaking while
handling.
FIRST STARTING-UP OF THE HYDRAULIC OIL
PUMP
An appropriate start of the pump is of the utmost
importance, since the correct lubrication of the
internal parts of the pump depends on this phase.
- Start the pulse-operated electric motor in order to
allow for the priming and the lubrication of the
pump parts.
- Check that the direction of rotation is correct with
respect to the indication shown on the motor grid
and on the coupling flange of the pump.
- The priming of the pump is not only shown on the
pressure gauge mounted on the delivery pipe, but
also by the change in the noise of the pump, as it
becomes more silent when it has been successfully primed.