8 - TROUBLES - CAUSES - CURES
SIR-52-P/F
EN
8 - Pag. 3 / 6
8.3
DEVICE INTRODUCING BARS INTO GUIDES - PROBLEMS
ERROR CAUSE CURE
Levers stop in a lower
position because they are
misaligned
Adjust the loading levers
BAR DROPS OUTSIDE THE
LOWERING ROLLERS
Torn rollers
Replace the control levers rollers
The cylinder does not work
Check the operation of the levers
control cylinder.
ARMS DO NOT LOWER
Levers are jammed in a high
position.
Check there are no crosswise bars
or folded levers
The lateral cylinders do not
work.
Check the operation of the bar
introducing cylinder.
ARMS DO NOT INTRODUCE
BARS
Levers are misaligned and
interfere with the guiding
sprockets.
Position the levers in the loading
cycle.
CLOSED SPROCKETS
PREVENTING THE BAR FEEDING
Jammed sprockets
Clean and check sprockets, making s
Summary of Contents for SIR 52 F
Page 4: ......
Page 20: ...EN 2 TECHNICAL INFORMATION SIR 52 P F 2 Pag 12 16 2 6 TECHNICAL INFORMATION ...
Page 50: ...EN 4 HANDLING AND INSTALLATION SIR 52 P F 4 Pag 22 22 ...
Page 126: ...EN 8 TROUBLES CAUSES CURES SIR 52 P F 8 Pag 6 6 ...
Page 130: ...EN 9 PART REPLACEMENT SIR 52 P F 9 Pag 4 4 ...
Page 136: ...EN 10 GUIDE CHANNELS BAR PUSHER REVOLVING TIPS SIR 52 P F 10 Pag 6 6 ...
Page 147: ...11 COLLETS SIR 52 P F EN 11 Pag 11 34 ...
Page 165: ...11 COLLETS SIR 52 P F EN 11 Pag 29 34 ...
Page 174: ...EN 12 LIST OF AFTER SALES CENTERS SIR 52 P F 12 Pag 4 4 ...