6 - USE AND OPERATION
SIR-52-P/F
EN
6 - Pag. 23 / 24
6.11
EEPROM LOADING PROCEDURE
In case of programme deletion or eeprom
replacement, the programme needs to be loaded
again by adopting the following procedure.
INFORMATION
The procedure is appropriate for 1AE04
version CPUs and the subsequent
versions (example: 1AE05, 1AE06,
etc.).
- Power the bar feeder.
- Disconnect the CPU by turning selector A to
position (fig. 10).
- Position selector (B) on RUN-P.
- Power the CPU by turning selector A to position
. Wait until the STOP (C) light starts flashing.
- Position selector (B) on MRES, and keep it in
that position until the STOP (C) warning light
stops flashing and remains constantly on.
- Turn selector (B) to position RUN. If the
procedure has been followed correctly, the
RUN (D) warning light should flash for a while
and then remain constantly on, and the
programme should be loaded.
CAUTION:
After loading the programme, the parameters are to be reset; call the IEMCA
Service Department.
6.11.1 Cold start
Cold start occurs according to two different procedures.
ADVANCED AUTOMATIC START
Program the advanced automatic start following the procedures described in the "Push-button
panel operation and instruction manual", paragraph "Operator's parameters - description and
entering".
MANUAL START
- Make sure that all guards are closed and the emergency push-buttons are not pressed.
Summary of Contents for SIR 52 F
Page 4: ......
Page 20: ...EN 2 TECHNICAL INFORMATION SIR 52 P F 2 Pag 12 16 2 6 TECHNICAL INFORMATION ...
Page 50: ...EN 4 HANDLING AND INSTALLATION SIR 52 P F 4 Pag 22 22 ...
Page 126: ...EN 8 TROUBLES CAUSES CURES SIR 52 P F 8 Pag 6 6 ...
Page 130: ...EN 9 PART REPLACEMENT SIR 52 P F 9 Pag 4 4 ...
Page 136: ...EN 10 GUIDE CHANNELS BAR PUSHER REVOLVING TIPS SIR 52 P F 10 Pag 6 6 ...
Page 147: ...11 COLLETS SIR 52 P F EN 11 Pag 11 34 ...
Page 165: ...11 COLLETS SIR 52 P F EN 11 Pag 29 34 ...
Page 174: ...EN 12 LIST OF AFTER SALES CENTERS SIR 52 P F 12 Pag 4 4 ...