MSD-72 series Command Guide
49
@GSM / @SSM
Automatic measurement when unregistered signal is input
Getting
Command
@GSM
Response
@GSM, mode
Setting
Command
@SSM, mode
Response
@SSM, mode
Parameter
mode: Automatic measurement
0 = Not execute, 1 = Execute [Default]
Getting
example
Command
Response
@GSM
@GSM,1
Description Getting the set automatic measurement mode when unregistered signal is input.
Setting
example
Command
Response
@SSM,1
@SSM,1
Description Setting the automatic measurement to be executed when unregistered signal is
input.
Remarks
-
@RTT
Loading device data
Setting
Command
@RTT, ch (, table)
Response
@RTT, ch (, table)
Parameter
ch: Input channel
1 = IN1 to 9 = IN9
table: Device table
1 to 99 (Registered device data),
100 to 100+n (Preset device
data. ”n” varies depending on input signal, but
0 for most cases.)
Only for analog input, specify the device table.
Setting
example
Command
Response
@RTT,1
@RTT,1
Description Reconfiguring IN1 input timing setting to the value detected automatically.
Setting
example
Command
Response
@RTT,6,2
@RTT,6,2
Description Setting IN6 input timings to the values saved in the device table 2.
Remarks
This command is valid only if signal is input.
For analog input, this command is valid only if the device data of input signal is
registered.