MSD-72 series Command Guide
73
@GSP / @SSP
The number of speakers (cont
’d)
Getting
example
Command
Response
@GSP,1
@GSP,1,6,0,1,2,3
Description
Getting the IN1 speaker configuration.
Six speakers (Front Left / Right, Low Frequency Effect, Front Center, Rear Left /
Right) are used.
Setting
example
Command
Response
@SSP,2,8
@SSP,2,8
Description
Setting IN2 speaker configuration to Front Left / Right, Low Frequency Effect,
Front Center, Rear Left / Right, Rear Left / Right Center (eight speakers).
Completed normally.
Setting
example
Command
Response
@SSP,3,8,0,3,5,6,7
@ERR,1
Description
Setting IN3 speaker configuration to Front Left / Right, Rear Left / Right, Front
Left / Right Center, Rear Left / Right Center, Front Left / Right Wide.
The number of speakers is 10 which exceeds the settable value, and it causes
the error.
Remarks
These commands are only for digital input.
IN8 and IN9 are available only when
“1” (Digital signal). is selected for “
”.
If
“0” (Analog signal) is selected, “-1” is returned.
@RME
Copying EDID
Setting
Command
@RME, out, number, name
Response
@RME, out, number, name
Parameter
out: Connector to be loaded
1 = OUT1 to 4 = OUT4
number: Destination COPY DATA number
1 to 8
name: COPY DATA name
Up to 10 characters using 20 to 7D from ASCII codes.
You can skip this setting. In this case, only EDID settings are saved without
changing currently saved name.
Setting
example
Command
Response
@RME,1,1
@RME,1,1
Description Loading EDID data of the sink device connected to OUT1 and saving it in COPY
DATA 1.
Setting
example
Command
Response
@RME,3,4,800x600
@RME,3,4,800x600
Description Loading EDID data of the sink device connected to OUT3, naming it
“800x600”
and saving it in COPY DATA 4.
Remarks