MSD-72 series Command Guide
81
@GEC / @SEC
Control command (Communication command) (cont
’d)
Getting
example
Command
Response
@GEC,1
@GEC,1,10,1,POWER,7,5057204F4E0D0A,1000,2,500,0,0,1,2
Description
Getting settings registered in control command 1.
・
Delay: 10 ms.
・
Output port: RS-232C CH1
・
Memo: POWER
・
Data size: 7 bytes
・
Command data
: PW ON
CR LF
(ASCII codes)
・
Timeout: 1000 ms.
・
Retry: 2 times
・
Retry interval: 500 ms.
・
Retry over: Stop
・
Received data: Not displayed
・
Response command: Check 1 and 2
Setting
example
Command
Response
@SEC,2,0,1024,IN1 SELECT,10,405353572C312C310D0A,0,0,0,1,0
@SEC,2,0,1024,IN1 SELECT,10,405353572C312C310D0A,0,0,0,1,0
Description
Setting control command 2 as follows:
・
Delay: 0 ms.
・
Output port: LOOP BACK
・
Memo: IN1 SELECT
・
Data size: 10 bytes
・
Command data: @SSW,1,1 CR LF (ASCII codes)
・
Timeout: 0 ms.
・
Retry: 0 time
・
Interval: 0 ms.
・
Retry over: Execute
・
Received data: Not displayed
・
Response command: Not checked
Remarks
-