MSD-72 series Command Guide
67
3.3.10 EDID
@GED / @SED
EDID
Getting
Command
@GED
Response
@GED, edid_1, edid_2, edid_3, edid_4, edid_5, edid_6, edid_7, edid_8, edid_9
Setting
Command
@SED, ch_1, edid_1 (, ch_2, edid_2
・・・
)
Response
@SED, ch_1, edid_1 (, ch_2, edid_2
・・・
)
Parameter
edid_1-9: EDID
0 = Built-in EDID [Default],
1 = OUT1 MONITOR,
2 = OUT2 MONITOR,
3 = OUT3 MONITOR,
4 = OUT4 MONITOR,
101 to 108 = COPY DATA 1 to COPY DATA 8
ch_1-9: Input channel
0 = All digital inputs, 1 = IN1 to 9 = IN9
Getting
example
Command
Response
@GED
@GED,0,0,0,3,0,0,0,0,0
Description Getting the set EDID.
IN4: EDID of the sink device that is connected to OUT3.
Other inputs: built-in EDID
Setting
example
Command
Response
@SED,2,3
@SED,2,3
Description Setting IN2: EDID that is read from the sink device connected to OUT3.
Remarks
These commands are only for digital input.
IN8 and IN9: If
“0” (Analog signal) is selected for “
”, “-1” is acquired
and the setting cannot be valid. In order to use a copied data, read EDID data
from the sink device in
” in advance.