![IDK HDC-TH200 User Manual Download Page 44](http://html1.mh-extra.com/html/idk/hdc-th200/hdc-th200_user-manual_3729898044.webp)
HDC-TH200 User Guide/Command Guide
44
8.5 Analog video timing
8.5.1 [ F08 ] Automatic measurement
Analog RGB/analog YPbPr input video is measured to set automatically.
The HDC-TH200 has standard video timing formats settings. Normally the HDC recognize video input signals
and use pre-registered standard timing formats.
This menu is used for if the HDC cannot recognize video format or video is not recognized correctly with
standard timing formats.
If composite/S-
video signal is input, only “CLr” and “oFF” are available.
If there is no analog input, this menu shows “- - -”.
Setting value
CLr
: Initializing timing format setting for current input signal
oFF : Do not change current timing format setting [Default]
on
: Auto recognized aspect ratio (4:3, 16:9, 5:3, 5:4, or 16:10)
4.3
: Executing automatic measurement with 4:3 aspect ratio
16.9 : Executing automatic measurement with 16:9 aspect ratio
5.3
: Executing automatic measurement with 5:3 aspect ratio
5.4
: Executing automatic measurement with 5:4 aspect ratio
16.10 : Executing automatic measurement with 16:10 aspect ratio
●
Can be measured:
●
Cannot be measured:
- Input video contacts the circumscribed rectangle.
- Right and left sides of input video do not touch
the circumscribed rectangle.
- Brightness of input video is 25% or more.
- Brightness of input video is 24% or less.
Area has to be displayed
Sink device screen
Area that the brightness is more than 25%
Area has to be displayed
Area that the brightness is more than 25%
Sink device screen
[Fig. 8.6] Condition for automatic measurement