7.4 Input channel remote switching
Input channels can be switched via an
IDK’s HDBaseT product (Digital multi switchers, Modular matrix
switchers, and extender) using the communication command,
【
See: 8.2.1 [ F05 ] Priority of input channel automatic switching
【
See: @GSW / @SSW Switching input channel
Example: Switching HDC input channel from analog to digital video via the MSD-802UHD.
・
“@SSW,1,1” command is sent from the PC that is connected to the RS-232C connector of the
MSD-802UHD.
・
The “@SSW,1,1” command is sent to the HDC that is connected to the HDBaseT input connector of the
MSD-802UHD.
・
The input channel of the HDC is switched from analog video input to HDMI input.
Laptop
RS-232C
PC
HDC-TH200
Blu-ray player
HDMI/DVI
Up to 98 ft. (30 m)
Analog RGB
DVD player
Composite
video
Analog YPbPr
VHS
Y/C
Video camera
Monitor
HDMI/DVI
@SSW,1,1
HDBaseT
@SSW,1,1
[Fig. 7.4] Switching input channel remotely
Note:
The HDC
’s LAN port does not receive commands.
RS-232C Settings of the HDC and the other HDBaseT product should be matched.
【
See: 8.8.4 [ C14 ] RS-232C communication speed
【
See: 8.8.5 [ C15 ] RS-232C communication data bit length
【
See: 8.8.6 [ C16 ] RS-232C communication parity check
【