MorphoWave
TM
OEM
– Installation guide
Section 3 :Installation Procedure
60
IDEMIA
D
OCUMENT
–
R
EPRODUCTION AND
D
ISCLOSURE
F
ORBIDDEN
2015_2000009096 V6
January 2019
Ethernet connection
Ethernet interface can be used to power the MorphoAccess Sigma Wave terminal
through POE (Power Over Ethernet - IEEE802.3af) mode. According to the POE standard
two modes are available: power on data pins and power on dedicated pins.
Use either one of these modes depending on POE implementation on your local
Ethernet network.
Ethernet cable shall be shielded
Default Ethernet configuration
By default, MorphoAccess Sigma Wave terminal is configured in Static mode.
IP address Mode
Parameter
Factory value
Static
Terminal IP address
192.168.1.10
Gateway IP address
192.168.1.254
Sub network mask
255.255.254.0
Host name
MAsigma
Connecting MorphoAccess Sigma Wave terminal with default Ethernet
configuration
Administrator must change the default Ethernet configuration before deploying
terminal on site. This can be achieved by several ways as mention below.
Terminal LCD Menu > Communication Menu > Network Interface > Ethernet
MBTB > Quick Configuration > Communication Configuration > IPv4 Address
Settings
Webserver > Terminal Settings > Communication > IPv4 Network
Prior to connecting through MBTB or Webserver, please check if Terminal is accessible
from Host system/PC or not. To access terminal which is having default network
parameter, the administrator may need to modify the network parameters of the Host
PC.
Please refer to following example to connect terminal which is having default network
parameter.