MorphoAccess Sigma & PC internal connection checking
From the PC Wave, it is possible to ping the MorphoAccess Sigma on the internal
network so as to verify Ethernet link is fine between both devices.
Please follow instructions below:
-
Apply “Remote PC Wave connection for maintenance” procedure to be
connected on PC.
-
Launch console application and type
ping 169.254.169.101
If the ping is not successful, please verify power supply of MorphoAccess Sigma,
Ethernet switch, and Ethernet wire connection.
To sum up IP static IP address used on the internal Network:
Components
Static IP address on internal network
MorphoAccess Sigma Wave
169.254.169.101
PC Wave
169.254.169.102
NB: As a reminder, it is not possible to ping these IP address from customer network
because the internal network is isolated from the port “External” of the Ethernet switch.