MorphoWave
TM
OEM
– Installation guide
Section 3 : Installation Procedure
2015_2000009096 V6
January 2019
IDEMIA
D
OCUMENT
–
R
EPRODUCTION AND
D
ISCLOSURE
F
ORBIDDEN
51
Figure 26: Wiegand input wiring (Revision 2)
20 Black
/ Red
Digital ground
Ground for Wiegand
22 Green
/ Red
WIEGAND_IN0 In
Wiegand IN D0
(Output type required: Open drain
or 5V+/-5%)
23 White
/ Red
WIEGAND_IN1 In
Wiegand IN D1
(Output type required: Open drain
or 5V+/-5%)
10 Yellow LED
Out
Wiegand LED OUT 1 (typical = 5V)
(option) :
If pull-up’s to 12V have been added on D0_IN and D1_IN inputs for
MA5XX product, these resistors must be removed to avoid any damage.
Wiegand output wiring
The following figures show how to cable the wires of the serial port of the terminal for
the Wiegand protocol
Figure 27: Wiegand output wiring (Initial version)
A
5
Digital ground
Ground for Wiegand (connect pin 5 or 6)
6
Digital ground
Ground for Wiegand (connect pin 5 or 6)
B
3
D0_OUT
Out Wiegand OUT D0 (5V TTL)
4
D1_OUT
Out Wiegand OUT D1 (5V TTL)
1
6
1
6
1
6
1
6
A
B
C