MorphoWave
TM
OEM
– Installation guide
Section 3 : Installation Procedure
2015_2000009096 V6
January 2019
IDEMIA
D
OCUMENT
–
R
EPRODUCTION AND
D
ISCLOSURE
F
ORBIDDEN
49
Operating principle for the switch
Product installed on the wall plate: switch enabled (contact closed).
Product opened (rear connectors accessible): switch disabled (contact open).
Nominal characteristics of switch block
100 mA at 30 VDC max (Resistive load) according to the safety extra low voltage
standard.
This MorphoWave
TM
OEM terminal is part of security system; it is
customer’s responsibility to connect the tamper switch (contact) to
physical access controller, in order to prevent the access to the connector
blocks.
Integrator Tamper Switch
Figure 23: Integrator Tamper switch wiring
C
3
Switch 1
Integrator
6
Switch 2
tamper switch
Figure 24: Integrator Tamper switch wiring (Revision 2)
13 Orange / Black
Switch 1
In
Integrator
14 Yellow / Black
Switch 2
Out
tamper switch
1
6
1
6
1
6
1
6
A
B
C
D