Wiegand port wiring
Wiegand input wiring
The following figure shows how to cable the wires of the “Wiegand In” port of the
terminal for Wiegand protocol. This is used, for instance, to connect an external card
stripe reader to the MorphoAccess® VP MD terminal.
Figure 16: Wiegand input wiring
18 Black / Red
Digital ground
Ground for Wiegand
19 Green / Red
WIEG_IN_D0
In
Wiegand IN D0
(Output type required: Open
drain or 5V+/-5%)
20 White / Red
WIEG_IN_D1
In
Wiegand IN D1
(Output type required: Open
drain or 5V+/-5%)
If pull-up’s to 12V have been added on D0_IN and D1_IN inputs on a
previous installation with a MorphoAccess® 500 Series terminal, these
resistors must be removed to avoid any damage to the MorphoAccess® VP
MD terminal.