Safety Instructions
means Direct Current (DC)
The installation of this product should be made by a qualified service Person and should
comply with all local regulations.
It is strongly recommended to use a class II power supply at 12VDC 1A minimum in
conformity with Safety Electrical Low Voltage (SELV). The power supply cable length
should not exceed 10 meters.
This system must be installed in accordance with the National Electrical Code (NFPA
70), and the local authority having jurisdiction.
This product is intended to be installed with a power supply complying with IEC60950-
1, in accordance with the NEC Class 2 requirements; or supplied by a listed IEC60950-1
external Power Unit marked Class 2, Limited Power source, or LPS and rated 12VDC, 1A
minimum or 24VDC, 0,5A minimum.
In case of building-to-building connection (power source in a building, and terminal in
another building), it is recommended to connect the 0V of the power supply to the
earthing system of the building. And the terminal block Power Ground must be
connected with the earthing system of the other building.