S1 (source 1) setting
(1) Input character string
Specify a character string within a maximum length of 1,023 bytes, regardless of whether single-byte or double-byte
characters are used. When multiple lines are entered, the line feed character (0D0Ah) is inserted between those lines.
■
D1 (destination 1) setting
(2) First DR
Specify the first data register of the data registers where the character string is stored.
■
Other settings
(3) Device range
The device range displays the range of data registers, starting from the specified data register, that are required to store the
character string specified by the input character string (1).
The range of data registers is not displayed in the following cases:
• The byte length of the character string specified by the input character string (1) exceeds 1,023 bytes.
• A device other than a data register (excluding special data registers) is specified as the first DR (2), or the first DR (2) is not
configured.
Note:
The device range is displayed as follows when the specified data registers are out of range.
(4) Character set
Select the character set of the character string from the following six types of character sets:
• ASCII
• Unicode (UTF-8)
• Japanese (ISO-2022-JP)
• Japanese (Shift-JIS)
• Chinese (GB2312)
• Western European (ISO 8859-1 (Latin 1))
(5) Character string size
The character string size displays the byte length of the input character string.
The displayed value is the byte length of the input character string (1) plus the NULL terminator (1 byte) added to that
character string.
(6) Decoded input character string
The character string input in Input character string (1) is decoded with the character set specified by Character set (4) and
displayed in this text box.
Summary of Contents for MICROSmart FC6A Series
Page 1: ...B 1726 7 FC6A SERIES Ladder Programming Manual ...
Page 8: ...Preface 7 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Page 32: ...1 OPERATION BASICS 1 20 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Page 96: ...3 INSTRUCTIONS REFERENCE 3 18 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Page 130: ...4 BASIC INSTRUCTIONS 4 34 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Page 192: ...9 SHIFT ROTATE INSTRUCTIONS 9 12 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Page 272: ...12 DISPLAY INSTRUCTIONS 12 24 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Page 284: ...14 REFRESH INSTRUCTIONS 14 6 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Page 502: ...25 DATA LOG INSTRUCTIONS 25 22 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Page 546: ...26 SCRIPT 26 44 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Page 598: ...APPENDIX A 14 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...