22
Mar 2016
MSC-18K
4.5 OTHER MESSAGES EXPLAINING
MESSAGE
EXPLAINATION
1
PLC err, check &
repower
a. Communication between master and slave columns failed. (bad
cable connection, antenna problem or some PLC lack of
power.)
b. Some PLC not working
Note: must be power off for checking then power on again
2
Encode
err,
WHEEL/AXLE!
a. Some encoder is not working ( not powered, bad wired or in
error
b. Bad communication( wireless model)
3
Asynch! WHEEL /
AXLE mode
a. Too big difference in height reading (>1700mm), caused by
over turning
b. Some column not move (motor not running, carriage locked)
c. Some encoder not turning( belt left the gear)
4
24Vdc insufficient
After moving stopped, one or more columns were found battery in
low voltage. The lift will not raise up any more but may lower
down.
5
Locked by abnormal
ope.
One button is pressed within 2’ after previous button is released.
6
Stop!
a. Emergency button is pressed.
b. Communication between columns is broken.
c. One or more column is power off.
d. Within 2 second after button is released.
7
Manual adj.! Max.
<5s / time
Manually adjust column height. Maximum single operation for 5
seconds per time..
8
Reset ! xx time
xx min.
RESET state: one lift height is below 5 cm when in ALL mode. Lift
will be back in ZERO bias.
Free movement is possible and pair of column can be added or
taken away.
Any operation will leave this RESET state.
9
Reach end of travel
One column stops after reaching its height limit. (this column will
not raise when lower down)
Summary of Contents for MSC-18K-B
Page 5: ...4 Mar 2016 MSC 18K 1 2 DIMENSIONS mm inch Fig 1 Mobile Column Lift Dimensions...
Page 34: ...33 Mar 2016 MSC 18K MSC 18K B EXPLODED VIEWS PARTS LISTS MSC 18K Column Assembly...
Page 39: ...38 Mar 2016 MSC 18K MSC 18K Control Panel Assembly...
Page 41: ...40 Mar 2016 MSC 18K MSC 18K Power Unit Assembly...