3.5 TRAVEL DISTANCE, HEIGHT UNIT AND UNIFORM CHANGING
3.5.1 TRAVEL DISTANCE AND HEIGHT UNIT CHANGE
If the lifting height is less than 67” (170cm) due to low shop ceiling, the travel distance
shall be set in following steps before starting the lifting operation.
1. After power on, waiting the LCD screen to be the LCD screen 4th, then press ESC
button to change into system menu. ( LCD screen 5
th
)
2. When ‘USER MENU’ is high-lighted, press ENTER button to enter the sub menu of
USER MENU. ( LCD screen 6
th
)
LCD screen 5
th
LCD screen 6
th
LCD screen 7
th
3. Press DIRECTION DOWN button to move to ‘Set of Unit/Stroke’ as in LCD screen
6
th
.
4. Press ENTER button again to enter the unit and travel distance modification screen.
(LCD screen 7
th
)
5. To change the unit, using ‘DIRECTION‘ UP and DOWN buttons to change the
number on the right-up corner. ‘1’ refers to inch. ‘0’ refers to cm.
6. To change the travel distance, using ‘DIRECTION‘ buttons and to move cursor to the
percentage on the screen then change the number.
Note: The percentage range is 60%--100%. Min. step is 2” (5cm).
7. Press ENTER to confirm the modification and press ESC to exit this function to
upper menu. (LCD screen 6
th
)
8. Press ESC button twice to get back to LCD display 4
th
USER MENU
OPERATOR MENU
DIAGNOSTICS MENU
RELEASE PASSWORD
Operation prompts
Encoder alignment
Set of Unit / Stroke
Unit: 0—cm; 1—inch
00
max. 68-100 % stroke
170 X
100
= 170 cm
Press ENTER then ESC
Summary of Contents for MSC-18K-B
Page 5: ...4 Mar 2016 MSC 18K 1 2 DIMENSIONS mm inch Fig 1 Mobile Column Lift Dimensions...
Page 34: ...33 Mar 2016 MSC 18K MSC 18K B EXPLODED VIEWS PARTS LISTS MSC 18K Column Assembly...
Page 39: ...38 Mar 2016 MSC 18K MSC 18K Control Panel Assembly...
Page 41: ...40 Mar 2016 MSC 18K MSC 18K Power Unit Assembly...