29
Mar 2016
MSC-18K
9. CHANGE THE NUMBER OF COLUMNS
Normally the mobile column lift set is working with four columns. But it can work only
with two columns (only 1# and 2# column)
.
To take away columns (4
→
2), please do as following.
Step 1
Lower down all the columns to ground till ‘RESET!’ appears on the screen.
Step 2
Turn off the power switch of each control units.
Step 3
Disconnect the cable between column 1#--3#, 2#--4#.
Step 4
Turn on the power switch of the control unit on desired columns (2# and 1#)
again.
Step 5
After self-check, now the system is working with only two columns.
To add columns (2
→
4), do above steps except in Step 3 is to connect the cables from
1#--3#, 2#--4# and in Step 4 turn on all the power switches on columns.
NOTE:
To lower down all columns to ground and to wait for RESET! APPEAR ON THE
SCREEN is necessary.