32
Mar 2016
MSC-18K
12. BATTERY REQUIREMENT INFORMATION
Battery Quantity:
2ea per Column -
(Not included with MSC-18K-B)
Battery Dimension:
13" L x 7" W x 12" H (Max size)
Battery Cover Size:
15" L x 8" W x 14" H
Battery Type:
Deep Cycle Batteries, 12VDC
Battery Rating:
120 AMP / HR
Battery Start Current: 350 CCA - 500 CCA
Suggestions:
1.
When “Low voltage on “ or “ Voltage deficient” is on the screen, lower down the
vehicle, shut off the lift, then charge the batteries at once. Continue to use the
batteries will short the life of batteries.
2.
Charge the batteries immediately after the job is finished. This will help to prolong
the life of the batteries.
3.
When in storage, the batteries shall be fully charged first. Every six months charge
again. Discharge the batteries once a year at 30% then charge fully.
4.
It is better to disconnect & remove the batteries from the lift for long period storage
and keep it indoors.
5.
Check the battery once a month for out looking, output voltage (open circle) and
etc. to keep it in a good condition.