MSC-18K
FAULT
POSSIBLE CASE
REMEDY
Column
Does not
Lift
Properly.
Oil level in tank too low.
Add oil as necessary; refer to lubricating
instructions on lifting column.
Pump drawing-in air.
Tighten the suction filter fastening or crimp
tighter.
The steel plug has not been
replaced by the breather cap
Install the breather cap
Breather cap blocked.
Clean breather cap.
Column
Height
Reading
not
Reach
Zero
Sensor zero point not
correct
Do encoder alignment
No
Control
Power
Fuse blown.
Check the fuses F1, F2 and F3. If necessary,
replace the fuse(s) in the control box. If fault
occurs again, contact the Service
Department.
Power switch is OFF.
Set power switch to ON.
Broken cable or loose
connector.
Check cable and connector.
The emergency stop button
has not been unlocked.
Release the emergency button. Set the main
switch(es) to OFF and ON.
FAULT
POSSIBLE CASE
REMEDY
No
Power
No power supply.
Have fault corrected by qualified electrician.
Main fuse blown.
Replace fuse.
(Power
Indicator
are Off)
Main switch(es) OFF.
Set power switch(es) ON.