8. ELECTRO-OPTICAL ENCODER ALIGNMENT
The lifting height is detected by the sensor called encoder. The zero point of the sensor
is checked in following steps.
1. Lower down all the columns to bottom.
2. Press ESC button [18] to enter USER MENU. (LCD screen 5
th
)
3. Press DIRECT down button [8] to choose ENCODER ALIGNMENT. See LCD
screen 6
th
4. Press ENTER button.
5. In this screen, the numbers on bottom line is the zero height code of each
column. If any one is not between 1 and 7, adjustment shall be done. LCD screen
14
th.
6. To adjust, please open the upper cover on the column. Then separate the strip
from the gear of the sensor.
7. Turn the gear to increase or decrease the reading on the corresponding column.
The best value is 5. Value between 1 and 7 is acceptable.
8. Put on the strip again. Check again the readings. If OK, close the upper cover.
LCD screen 5
th
LCD screen 6
th
LCD screen 14
th
USER MENU
OPERATOR MENU
DIAGNOSTICS MENU
RELEASE PASSWORD
Operation Prompts
Encoder Alignment
Set of Unit / Travel
1. Forks move onto floor
2. Readings must be 3, 5 ,7 or 1
mm : 3 5 1
C-wise + 1 1 3