![background image](http://html1.mh-extra.com/html/ics/linker-iia/linker-iia_user-manual_3528704068.webp)
67
FUNCTION:
PROGRAM TERMINATOR DIGIT
FUNCTION CODE:
131
PURPOSE:
Allows the selection of the terminator digit
HOW TO USE:
1.
Key up
2.
Enter the PROGRAM TERMINATOR DIGIT function code
3.
Unkey
4.
The controller sends ENTER NEXT DATA indication
5.
Enter the new terminator digit
6.
Unkey
7.
The controller sends the COMMAND ACCEPTED indication
8.
The terminator digit is now stored. The controller will use new digit as the terminator.
This function is available starting with V1.21 f the Linker II and Linker IIa software.
FUNCTION:
TERMINATOR CONTROL
FUNCTION CODE:
132
PURPOSE:
This function enabling or disabling of the terminator..
HOW TO USE:
1.
Key up
2.
Enter the TERMINATOR CONTROL function code
3.
Unkey
4.
The controller sends ENTER NEXT DATA indication
5.
Enter a ‘1’ to enable the terminator or a ‘0’ to disable the terminator
6.
Unkey
7.
The controller sends the COMMAND ACCEPTED indication
8.
If a ‘1’ was entered the terminator digit is now active..
This function will allow you to enable or disable the terminator. Entering a ‘1’ enables the terminator and entering
a ‘0’ disables the terminator.
The default status (factory default) is the terminator is active in software versions before 1.30.1.
The default status (factory default) is the terminator is NOT active in software version 1.30.1 and later. This
means the terminator must be enabled to use it in versions 1.30.1 and later.
To keep the current setting of this function you must use the SAVE STATUSES command (command #87). This
will insure the current status of this setting will be maintained upon power up and reset.
This feature is available starting with version 1.21 of the Linker II / Linker IIa software.