49
FUNCTION:
SET RX 2 CTCSS ON LEVEL
FUNCTION CODE:
95
PURPOSE:
Sets the voltage which when reached the control will consider this input to be on
HOW TO USE:
1.
Key up
2.
Enter the SET RX 2 CTCSS ON LEVEL function code
3.
Unkey
4.
The controller sends the ENTER NEXT DATA indication
5.
Key up
6.
Enter the CTCSS voltage ( 1v to 9v) that when reached the controller should consider RX 2 CTCSS to be ON
7.
Unkey
8.
When the controller sends the COMMAND ACCEPTED indication these values have been entered
9.
The new RX 2 CTCSS input voltage on level is stored in EEPROM
A cold or warm reset will be necessary to have the newly stored value used for RX 2 CTCSS
The voltage entered can be from 1V to 9V and can be entered down to 0.01V. If the entered voltage is not in the 1V
to 9V range or if it is the same as the ‘OFF’ voltage the controller will not save the entered voltage and it will give the
ERROR or BAD VALUE indication (B in CW) .
This sets the RX 2 CTCSS on voltage. When setting the voltage care should be taken not to set it to the exact voltage
measured because the actual voltage may not always be exactly the same. It is a good idea to set the voltage at a level
that is not quite at the final voltage the CTCSS reaches. This can help avoid problems if the voltage changes slightly.
FUNCTION:
USE ONLY RX 2 COS INPUT
FUNCTION CODE:
96
PURPOSE:
Changes the COS input which RX 2 uses to the RX 2 COS input only
HOW TO USE:
1.
Key up
2.
Enter USE ONLY RX 2 COS INPUT function code
3.
Unkey
4.
The controller sends the COMMAND ACCEPTED indication
5.
The RX 2 COS will now activate RX 2.
This function switches control for RX 2 to the RX 2 COS input.
To make this function permanent (Function stays active after power up or reset) the SAVE STATUSES function
(function # 87) must be used.