41
FUNCTION:
SET RX 1 COS VOLTAGE OFF LEVEL
FUNCTION CODE:
79
PURPOSE:
Sets the RX 1 voltage which when reached the control will consider
the receiver to be OFF
HOW TO USE:
1.
Key up
2.
Enter the SET RX 1 COS VOLTAGE OFF LEVEL function code
3.
Unkey
4.
The controller sends the ENTER NEXT DATA indication
5.
Key up
6.
Enter the COS voltage ( 1v to 9v ) that when reached the controller should consider RX 1 to be OFF
7.
Unkey
8.
The controller sends the COMMAND ACCEPTED indication
9.
The new RX 1 COS voltage off level is stored in EEPROM.
10.
A cold or warm reset will be necessary to have the newly stored value used for RX 1 COS
The COS voltage entered can be from 1V to 9V and can be entered down to 0.01V. If the voltage value entered is not
in the 1V to 9V range the controller will not save the entered data and it will give the ERROR or BAD VALUE
indication (B in CW) and the function will be ended.
This sets the RX 1 COS off voltage. When setting the voltage care should be taken not to set it to the exact off voltage
measured because the actual off voltage may not always be exactly the same. It is a good idea to set the off voltage at
a level that is not quite at the final voltage when the input switches. This can help avoid misread signals when the
system is in operation.
FUNCTION:
SET RX 1 COS VOLTAGE ON LEVEL
FUNCTION CODE:
80
PURPOSE:
Sets the RX 1 voltage which when reached the control will consider
the receiver to be ON
HOW TO USE:
1.
Key up
2.
Enter the SET RX 1 COS VOLTAGE ON LEVEL function code
3.
Unkey
4.
The controller sends the ENTER NEXT DATA indication
5.
Key up
6.
Enter the COS voltage ( 1v to 9v) that when reached the controller should consider the RX 1 COS to be ON
7.
Unkey
8.
When the controller sends the COMMAND ACCEPTED indication these values have been entered
9.
The new RX 1 COS voltage on level is stored in EEPROM.
10.
A cold or warm reset will be necessary to have the newly stored value used for RX 1 COS
The COS voltage entered can be from 1V to 9V and can be entered down to 0.01V. If the COS voltage value entered
is not in the 1V to 9V range the controller will not save the entered data and it will give the ERROR or BAD VALUE
indication (B in CW) and the function will be ended.
This sets the RX 1 COS on voltage. When setting the voltage care should be taken not to set it to the exact on voltage
measured because the actual on voltage may not always be exactly the same. It is a good idea to set the on voltage at a
level that is not quite at the final voltage when the input switches. This can help avoid misread signals when the
system is in operation.