ZT-2570/ZT-2571 

User Manual 

Warranty 

All products manufactured by ICP DAS are under warranty regarding 

defective materials for a period of one year, beginning from the date of 

delivery to the original purchaser. 

Warning 

ICP DAS assumes no liability for any damage resulting from the use of 

this product. ICP DAS reserves the right to change this manual at any 

time without notice. The information furnished by ICP DAS is believed to 

be accurate and reliable. However, no responsibility is assumed by ICP 

DAS for its use, not for any infringements of patents or other rights of 

third parties resulting from its use. 

Copyright 

Copyright © 2013 by ICP DAS. All rights are reserved. 

Trademark

 

Names are used for identification only and may be registered trademarks 

of their respective companies. 

Technology Support 

 

If you have any problems, please feel free to contact us via 
email at 

[email protected]

 

ГК

 

Атлант

 

Инжиниринг

 – 

официальный

 

представитель

 

в

 

РФ

 

и

 

СНГ

 

+7(495)109-02-08 [email protected] www.bbrc.ru 

Summary of Contents for ZT-2570

Page 1: ...thout notice The information furnished by ICP DAS is believed to be accurate and reliable However no responsibility is assumed by ICP DAS for its use not for any infringements of patents or other righ...

Page 2: ...lity Serial Ethernet 21 4 4 Configure ZigBee via Browser Ethernet 25 4 5 Configuration Example 30 4 5 1 Data Transparent 31 4 5 2 Modbus RTU communication 32 4 5 3 Modbus RTU to Modbus TCP communicati...

Page 3: ...e CD Napdos ZigBee ZT_Series Utility http ftp icpdas com pub cd usbcd napdos zigbee zt_series utility ZT 257x Device CD ANT 124 05 Release Note CA 0915 ZT 2570 CA 0910N ZT 2571 If any of these items a...

Page 4: ...r transmitter receiver able to reach all of the devices Any ZigBee device can be tasked with running the network ZigBee Application ZigBee is targeted at applications that require a low data rate long...

Page 5: ...nto 5 MHz sectors providing 16 channels and 16384 PAN IDs ZT 2000 series is not only a long distance wireless converter but also can act a ZigBee router to extend the transmission range and improve th...

Page 6: ...o set different configurations based on the type of application together with several of required ZigBee variables such as Pan ID The friendly user interface is also helping user be familiar with ZT 2...

Page 7: ...ication Interface COM 0 RS232 RS 232 TxD RxD and GND D Sub 9 Female Non isolated D Sub 9 Male Non isolated RS 485 RS 485 DATA DATA internal ASIC self tuner Non isolated Baud Rate 1200 115200 bps Data...

Page 8: ...dBm Antenna 2 4GHz 5 dBi Omni Directional Antenna Transmit Range LOS 700 m Typical Max Slaves Supported 255 EMC CE FCC FCC ID WARNING HOT SURFACE DO NOT TOUCH In compliance with the EN 60950 1 declar...

Page 9: ...details please see the section 6 troubleshooting 2 Operating Mode DIP Switch ZBSET Configuration mode is able to use browser or ZT Configuration Utility to configure via the Ethernet RS 232 or RS 485...

Page 10: ...PWR indicator will be steady light if correct power input 4 Ethernet The port RJ 45 jack is the 10 100 Base TX Ethernet port 5 RS 232 The RS 485 and RS 232 are communicable via the same UART 6 2 4 GHz...

Page 11: ...User Manual Version 1 3 Page 8 Copyright 2013 by ICP DAS Co Ltd All Rights Reserved 3 3 Dimensions Units mm Left Side View Right Side View Front View Rear View Bottom View Top View 7 495 109 02 08 sa...

Page 12: ...k Diagram 3 5 Wire Connection 1 RS 232 2 RS 485 D D D D CA 0915 GND RxD TxD CA 0910N ZT 2570 ZT 2571 TxD RxD GND ZigBee Module LED Display EEPROM Setting Switch RS 232 Interface RS 485 Interface Power...

Page 13: ...e The identity number must be unique if it is in the same ZigBee network as other ZigBee module Valid values range from 0x0001 to 0xFFF7 for a ZigBee Router but is fixed to 0x0000 for a ZigBee Coordin...

Page 14: ...LAN So the RF Channel 4 9 E and F of ZigBee are recommended in this case ZigBee WiFi CH 1 2412 CH 0 2405 CH 2 2417 CH1 2410 CH 3 2422 CH 2 2415 CH 4 2427 CH3 2420 CH 5 2432 CH 4 2425 CH 6 2437 CH 5 24...

Page 15: ...tes Data above 79 bytes will be transmitted in several packets This parameter decides the broadcasting frame sending interval time to avoid the network overloading User only fills in the number of ZT...

Page 16: ...imum The parameter adjustment purely personal behavior ICP DAS can not guarantee to pass CE FCC certification if adjusting this parameter nor assume any liability because of the adjustment parameters...

Page 17: ...led and it allows working with Ethernet at the same time b Ethernet Either TCP Server or TCP Client is enabled and it allows working with RS 232 or RS 485 at the same time c Virtual COM Virtual COM dr...

Page 18: ...with LAN of desktop Port User port will listen to connection request when it acts TCP Server Connection Target Need to set when it acts TCP Client IP The IP of connection target Port The port of conne...

Page 19: ...nicast Data will only be sent to the coordinator Eg1 When ZT 2570 ZigBee Host sends DATA_01 via broadcasting frame Both of the ZigBee slave 0x0001 and 0x0002 will receive the DATA_01 Broadcasting type...

Page 20: ...mat AAAA Data Eg1 When ZT 2570 ZigBee Host sends 0001DATA_01 via unicast frame Only the ZigBee Slave 0x0001 receives DATA_01 Unicast type frame data will be only sent to the specific ZigBee node Eg2 W...

Page 21: ...rotocol then output MTCP_CMD_01 to Ethernet Broadcasting type frame data will be sent to every ZigBee slaves in the same ZigBee network Eg2 When ZT 2570 receives data MTCP_CMD_02 from Ethernet ZT 2571...

Page 22: ...Vs pins with 10 to 30V power supply SAFTY INSTRUCTION NOTES Before connecting the power source to the power input pins ensure that both the installation of the unit in the completed system and the DC...

Page 23: ...gure the ZT 257x RS 232 RS 485 Ethernet Step 4 Enable the power It means that the ZT 257x start up procedure has been completed If the red LED has changed from blinking to a steady light ZT 2570 ZB 25...

Page 24: ...Single click either the Serial Port or Ethernet icon with the correct number of COM Port or IP Address that is used to select the communication interface 1 2 Serial Port Ethernet Double click the fie...

Page 25: ...r a list of model numbers will be displayed Select the name of the module that you want to configure After clicking the button the utility will begin checking the connection Step 4 Once a connection i...

Page 26: ...l Rights Reserved Step 5 Whether you select either the Default or the Wizard option for performing configuration both are used to configure the Pan ID Node ID RF Channel RF Power Baud rate Data Format...

Page 27: ...y ICP DAS Co Ltd All Rights Reserved Step 6 Once the module configuration has been completed the message The Configuration was successful will be displayed Return the DIP switch to the ZBRUN position...

Page 28: ...er software tools thereby reducing the user s learning curve Step 1 First please confirm the desktop and ZT 257x is installed in the same network environment The default network setting of ZT 257x as...

Page 29: ...ZT 257x device please click IP setting then it will show a windows form to do configuration c Please configure the new IP setting which is the same segment to the LAN of desktop Please also click the...

Page 30: ...After configuring the IP setting you may try to PING the device to see whether the configuration is correct or not Step 3 If they are in the same network environment user can use a browser to set the...

Page 31: ...web page will show all the configuration settings as below User may enter the new setting value to the correct filed if there are any requirements Step 5 If the new configuration is completed please c...

Page 32: ...l Rights Reserved Step 6 When the configuration completed and successful it will show The system is updated with new configurations Please reload the web page to see whether the configuration is corre...

Page 33: ...e RS 232 RS 485 Baud Rate Data Format Receive Interval 115200 N 8 1 3 5 character time 9600 E 8 1 3 5 character time User configurable The wired communication are independent to each ZT devices so the...

Page 34: ...will only be sent to ZigBee coordinator via unicasting Unless there are particular purposes Transparent Mode can be set up in most applications The only drawback is that the data throughput of ZigBee...

Page 35: ...Bee network will be reduced with the number of ZigBee routers in the ZigBee network increased in order to ensure data transmitted to every ZigBee nodes so that the transfer time will be much longer th...

Page 36: ...ed with the ZT 2551 71 of Node ID 0x0001 The Modbus RTU device of address 0x02 is only able to be connected with the ZT 2551 71 of Node ID 0x0002 and so on 2 If there are two or more Modbus RTU device...

Page 37: ...e number of ZigBee routers in the ZigBee network increased in order to ensure data transmitted to every ZigBee nodes so that the transfer time will be much longer than using unicast frame In Gateway M...

Page 38: ...sed for the wireless transmission In this setting the Node ID and Address of Modbus TCP device should be set to the same Please refer the following examples The Modbus TCP device of address 0x01 is on...

Page 39: ...data transmitted to every ZigBee nodes so that the transfer time will be much longer than using unicast frame In Gateway Mode the benefit of unicasting is that the loading of ZigBee network will be re...

Page 40: ...00 2 The standard of ZigBee does not include the TCP IP protocol so the whole Ethernet packets cannot be sent over the ZigBee wireless communication In the other words the two separate local area netw...

Page 41: ...013 by ICP DAS Co Ltd All Rights Reserved connecting the different IP addresses However now all the socket connections are linked to the ZT 2570 so please use the Modbus Address to distinguish the dis...

Page 42: ...parent Mode and Gateway Mode are available to be used in the side of ZigBee router There are not any different to be used the data responded by ZigBee router will only be sent to ZigBee coordinator vi...

Page 43: ...can be referred as below Change the frame type of ZT 2550 70 to the broadcast mode in the advanced configuration Set up the Address Mapping to redirect the unicast frame to the corresponding ZT 2551 7...

Page 44: ...o convert the signal between Ethernet and ZigBee All the Modbus communication are completed via the socket connection between the controller and ZT 2570 Although all the Modbus TCP data should be tran...

Page 45: ...d to be considered please refer the Advanced Configuration Frame Type for more details as below ZT 2550 ZT 2570 ZT 2551 ZT 2571 Application Mode Gateway Gateway Refer Advanced Configuration Frame Type...

Page 46: ...551 71 there are two methods can be referred as below Change the frame type of ZT 2550 70 to the broadcast mode in the advanced configuration Set up the Address Mapping in the ZT 2550 70 which is used...

Page 47: ...ne LAN via the ZigBee wireless communication As the described above the LANs of ZT 2570 and ZT 2571 are independent So no matter which Modbus TCP devices you want to connect all the connection target...

Page 48: ...n the DIP switch to ZBRUN position and reboot module Next please confirm the ZB Net LED indicator of ZigBee salves whether is steady lighted or not If the status of green LED indicator is steady light...

Page 49: ...u may need to use two serial port tools to simulate the data transmission Method 2 Use the DCON Utility on the Host PC to search for ZT 2000 series I O modules If there any devices are found it means...

Page 50: ...S7_Utility bin Send232 exe B Ethernet Test Method 1 Connect both the ZT 2570 and ZT 2571 to the Host PC via the Ethernet port You may need to use two TCP Server Client tools to simulate the data trans...

Page 51: ...nodes are across to the road building gutter or etc 2 ZT 257x is suitable to use in monitoring and controlling Eg Smart energy Home automation and etc Light Control Security Thermostat Window treatme...

Page 52: ...the configuration file for the ZT 257x module This file can be obtained using the procedure outlined below and should be attached to your email Step 1 Set the DIP switch of the ZT 257x device to the...

Page 53: ...ter Slave Steady Lit The Signal is Strong Blinking 500 ms The Signal is Available Blinking 1s The Signal is Weak Blinking 2s The Signal is Unstable or There is no Available ZigBee RxD Yellow LED The s...

Page 54: ...h is used to select either the Broadcast Frame or Unicast Frame to transmit data Once the Unicast Frame is selected the Address of DCON or Modbus instructions will be regarded as the destination addre...

Page 55: ...rresponding to the relative ZigBee module but there is an Address Mapping function supported for redirection to the correct destination address of ZigBee module User only fills in the relationship of...

Page 56: ...s send data to the user s controller via ZigBee the user program can not identify which device sends this data For example there are several barcode readers and RS 232 device connected to the ZT 2551...

Page 57: ...dressable Mode to show the Node ID of the remote ZigBee device which is connected to the user s end device When the advanced function is enabled the Node ID will be added in the AAAA format in front o...