ICP DAS, ZT-2570/ZT-2571 User Manual, Version 1.3
Page 16
Copyright @ 2013 by ICP DAS Co., Ltd. All Rights Reserved.
a.
Transparent Mode
is the default application mode, and always transmits
data to the remote device via broadcasting. Unless there are specific
purposes, the application mode can be retained as default.
The mode always bypasses data to remote side via broadcasting. If there
is no particular purpose, user only keeps this application mode.
Module
Frame Type
Note
ZT-2570 Broadcast
Data will be sent to all ZigBee slaves
ZT-2571 Unicast
Data will only be sent to the coordinator
[Eg1]
When ZT-2570 ZigBee Host
sends “
DATA_01
”
via broadcasting frame,
→
Both of the ZigBee slave 0x0001 and 0x0002 will receive the DATA_01.
※
Broadcasting type frame, data will be sent to every ZigBee slaves in the same ZigBee
network
[Eg2]
When the ZigBee slave 0x0001 sends
“
DATA_02
” via
unicast frame,
→Only ZT
-2570 receives DATA_02.
※
Unicast type frame, data will only be sent to the ZigBee host)
※
There is an “Advanced Settings” for some specific user
s, please refer the section
7.
3 ”Non
-
addressable Device Communication”
for more information.
ZC_0000
ZS_0001
ZS_0002
Transparent
Transparent
Transparent
DATA_02
DATA_03
DATA_01
DATA_01
DATA_01
DATA_02
DATA_03
ГК