ICP DAS, ZT-2570/ZT-2571 User Manual, Version 1.3
Page 50
Copyright @ 2013 by ICP DAS Co., Ltd. All Rights Reserved.
7
Appendixes
7.1
LED Indicator Status
LED Indicator Status
Introduction
ZigBee Net
(Green LED)
ZigBee Coordinator (Host)
Steady Lit
ZigBee network is Establish
Blink to Steady Lit Rejoin ZigBee Network or It has Occupied
ZigBee Router (Slave)
Steady Lit
The Signal is Strong
Blinking (500 ms) The Signal is Available
Blinking (1s)
The Signal is Weak
Blinking (2s)
The Signal is Unstable or There is no Available
ZigBee RxD
(Yellow LED)
The status of ZigBee communication
Blinking
Receiving ZigBee Data
Steady Unlit
No ZigBee Data Received
ZigBee PWR
(Red LED)
The status of module board
Steady Lit
Power ON
Blinking (200ms)
Module Initialization Failure
Blinking (200ms)
Configuration Mode
Blinking (1s)
Watchdog Enabled
Steady Unlit
Power OFF