![ICP DAS USA CL-200 Series User Manual Download Page 11](http://html1.mh-extra.com/html/icp-das-usa/cl-200-series/cl-200-series_user-manual_614324011.webp)
CL-200 Series User Manual Version 1.2.0 Apr. 2019
- 11 -
Wireless Security
-
AES 128
WEP, WPA ,WPA2
Transmission Range
-
20 m (LOS)
50 m (LOS)
Electrical
Powered via Terminal
Block
+12 to +48 VDC
Powered via PoE
IEEE 802.3af, Class 1 (require a PoE switch or injector)
Power Consumption
1.7 W
1.8 W
1.9 W
Mechanical
Dimensions (D x H)
Ø 150 mm x 53 mm
Installation
Ceiling Mounting or Wall Mounting
Environment
Operating
Temperature
0 to +50°C
Storage Temperature
-30 to +75°C
Humidity
10 to 90% RH, Non-condensing
Model
CL-202-E
CL-202-BLE
CL-202-WF
CO
2
Measurement
Range
0 ~ 9999 ppm
Resolution
1 ppm
Accuracy
±40 ppm ±3%
Response Time
120 seconds
Warm-up Time
5 minutes
Temperature Measurement
Range
-10 to +50°C
Resolution
0.1°C
Accuracy
±0.6°C
Relative Humidity Measurement
Range
0 to 100% RH, Non-condensing
Resolution
0.1% RH, Non-condensing
Accuracy
±5% RH, Non-condensing
Dew Point
Range
Calculated using temperature and relative humidity
Resolution
0.1°C