CAN-8123/CAN-8223/CAN-8423 user’s manual (Revision 3.00, May/22/2009) ------
147
11-bit COB-ID (bit)
Func Code
Node ID
8-byte Data (byte)
10 9 8 7 6 5 4 3 2 1 0
RTR
Data
Length
0
1
2
3 4 5 6 7
0 0 0 1 0 0 0 0 0 0 1
0
8
00 00 00
00
00 00 00
00
NMT master
NMT slaver
(CAN-8123/CAN-8223/
CAN-8423)
EMCY-msg
: 00 00 00 00 00 00 00 00
The data “00 00 00 00 00 00 00 00” are for the error reset EMCY
message, i.e. CAN-8423 has no error now.
Step 9. Users have to check the index 0x1003 with sub-index 01 again. Then,
the error reset emergency code should be recorded.
11-bit COB-ID (bit)
Func Code
Node ID
8-byte Data (byte)
10 9 8 7 6 5 4 3 2 1 0
RTR
Data
Length
0
1
2
3 4 5 6 7
1 1 0 0 0 0 0 0 0 0 1
0
8
40 03 10
01
00 00 00
00
SDO client
SDO server
(CAN-8123/CAN-8223/
CAN-8423)
ccs
: 2
m
03 10 01
11-bit COB-ID (bit)
Func Code
Node ID
8-byte Data (byte)
10 9 8 7 6 5 4 3 2 1 0
RTR
Data
Length
0
1
2
3 4 5 6 7
1 0 1 1 0 0 0 0 0 0 1
0
8
43 03 10
01
00 00 00
00
SDO client
SDO server
(CAN-8123/CAN-8223/
CAN-8423)
ccs
: 1
n
: 0
e
: 1
s
: 1
m
: 03 10 01
d
: 00 00 00 00