12
52
SPECIFICATIONS
■
General
• Minimum range:
25 m, 82 ft (when measurement range is
1
⁄
8
NM)
• Maximum range:
36 NM
• Measurement range:
1
⁄
8
,
1
⁄
4
,
1
⁄
2
,
3
⁄
4
, 1, 1.5, 2, 3, 4, 6, 8, 12, 16, 24, 32, 36 (NM)
• Preheat time:
90 seconds
• Connection length between display and scanner unit: 15 m, 49.2 ft
■
Display unit
• LCD display:
10.4-inch TFT Color
LCD
• Resolution:
480
×
640
• LCD mounting:
Vertical
• Input:
NMEA 0183 format (for navigation receiver),
N+1 format (fluxgate compass sensor),
AUX,
IEC61162-2 format (for AIS unit)
• Output:
NMEA 0183 format
• Power supply requirement:
10.2 to 42 V DC
• Power consumption (at zero wind velocity):
Approximately 55 W
• Usable temperature range:
–15˚C to +55˚C, +5˚F to 131˚F
• Dimensions (Mounting bracket is included):
301 (W)
×
323.5 (H)
×
119.2 (D) mm,
(Projections are not included)
11.8 (W)
×
12.7
(H)
×
4.7 (D) inches
• Weight (Mounting bracket is included):
Approximately 4.3 kg, 9.5 lb
■
Scanner unit (EX-2714)
• Type:
60 cm (2 ft.)
Slotted Waveguide Array, enclosed in a radome.
• Rotation speed (typical):
24 rpm, 36 rpm
• Beam width (typical):
Horizontal beam 4˚
Vertical beam
22˚
• Side lobe (typical):
–22 dB
• Polarization:
Horizontal
• Transmission frequency:
9410 MHz ±30 MHz P0N
• Peak output power:
4 kW
• Pulse width:
80 ns / 2160 Hz, 80 ns / 1440 Hz, 250 ns / 1440 Hz, 350 ns /
1440 Hz, 350 ns / 720 Hz, 900 ns / 720 Hz
• Mixer and Local Oscillator:
Microwave Integrated Circuit
• Transmitting Tube:
Magnetron
MAF1421B
• Modulator:
FET switching
• Duplexer:
Circulator
• Tuning system:
Automatic / manual selectable
• Intermediate frequency:
60 MHz
• IF Band width:
10 MHz, 3 MHz
• Dimensions:
640 (W)
×
256 (H)
×
640 (D) mm,
25.2 (W)
×
10.1
(H)
×
25.2 (D) inches
• Usable temperature range:
–25˚C to +70˚C, –13˚F to 158˚F
• Relative Humidity:
Less than 95% at 40˚C (+104˚F)
• Weight:
Approximately 8 kg, 17.5 lb (without cable)
■
Options
• OPC-2339
system
cable
Allows you to install the display unit and scanner up to 20 m (65.6 ft) apart.
• OPC-2340
system
cable
Allows you to install the display unit and scanner up to 30 m (98.4 ft) apart.
• UX-252
video
output
unit
Allows you to connect an external display or a PC monitor with a VGA connector.
All stated specifications are subject to change without notice or obligation.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21