![Icom ID-52A Advanced Manual Download Page 63](http://html2.mh-extra.com/html/icom/id-52a/id-52a_advanced-manual_3776585063.webp)
5
D-STAR OPERATION (ADVANCED)
5-22
EMR communication
The Enhanced Monitor Request (EMR) communication
function can be used in only the DV mode� Using the
EMR function, no call sign setting is necessary�
L
Information
• All transceivers that can receive an EMR signal
automatically receive the signal�
DO NOT
use this function
except in the case of an emergency�
• When an EMR signal is received, the audio (voice) is
heard at the set level, even if the volume setting level is
set to the minimum level�
• The EMR communication function is automatically turned
OFF when you turn OFF the transceiver�
[MENU] > SET > DV Set >
EMR
Example:
Transmitting from the “Hirano” repeater
using the EMR function�
1� Push [MENU]�
2� Select “DV Set” in the “SET” menu�
3� Select “EMR�”
4� Select “ON�”
5� Push [MENU]�
• Returns to the Standby screen and “EMR” is displayed�
Push [PTT]�
• The TX/RX indicator lights red while transmitting�
L
“EMR” blinks on a station that receives the EMR
signal� The audio (voice) is heard at the set level, or
the [VOL] level, whichever is higher�
L
To cancel the EMR mode, select “OFF” in step 4, or
turn OFF the transceiver�
D
Adjusting the EMR AF level
The audio output level when an EMR signal is
received is adjustable between 0 and 39�
When an EMR signal is received, the audio is heard at
the preset level, or the [VOL] control level, whichever
is higher�
To turn OFF the setting, set to “0�”
[MENU] > SET > DV Set >
EMR AF Level
1� Push [MENU]�
2� Select “DV Set” in the “SET” menu�
3� Select “EMR AF Level�”
4� Rotate [DIAL] to adjust the EMR audio output level
between 0 (OFF) and 39 (maximum)� (Default: 19)
L
To exit the MENU screen, push [MENU]�