ELEVATION SERIES CIM CUBERS
EVAPORATOR REPLACEMENT
47
While recovering the refrigerant from the unit,
disconnect High and Low Float Switches,
Thermistor, Curtain Switch and Push Pad ribbon and
move the wiring clear of the area.
Evaporator Cover
Float Switch Housing
Water Pump
Sump
Evaporator Top
Water Pump Tube & Connector
Splash Curtain
Connectors
Remove the Splash Curtain, Evaporator Cover, Top
Evaporator Cover, Water Distribution Tube,
Water Pump Tube and its connector, Sump, Water
Pump, and Float Switch Housing Assembly.
On the rear of the Evaporator Assembly, disconnect Harvest Assist Assembly, Purge Valve and
Purge Tube and remove from unit.
Harvest Assist
Assembly
Purge Valve
Clip Zip Ties holding Service Port tubes to rear of Evaporator. Remove 3) 1/4” screws on right side,
left side and center holding Evaporator Assembly to base.
Cut Zip Ties
Remove 1/4” screws