ELEVATION SERIES CIM CUBERS
GENERAL MAINTENANCE
56
Electrical shock and/or injury from moving parts inside this machine can cause serious injury.
Disconnect electrical supply to machine prior to performing any adjustments or repairs.
Failure to perform the required maintenance at the frequency specified will void warranty coverage
in the event of a related failure.
General Maintenance Procedure
To insure economical, trouble free operation of your machine; it is recommended that the following maintenance be
performed every 6 months.
1. Clean the ice-making section per the instructions below. Cleaning should be performed
a minimum of every 6 months. Local water conditions may require that cleaning be
performed more often.
2. Check ice bridge thickness. See page 10 for proper thickness and adjustment
procedure.
3. Check water level in Sump. See page 10 for proper water level and adjustment
procedure.
4. Clean the condenser (air-cooled machines) to ensure unobstructed air flow.
5. Check for leaks of any kind: water, refrigerant, oil, etc.
6. Check the bin control switch (if applicable) for proper adjustment.
7. Check the Water Regulating Valve (water cooled machine) for proper adjustment by
measuring the discharge pressure which should be adjusted to maintain 250 psi (17.01 bar/
1.723 MPa). Adjust the water regulating valve as required. Water exiting the condenser
should be between
100
°
F (38
°
C) and 110
°
F (43
°
C).
8. Check all electrical connections.
9. Oil the fan motor if the motor has an oil fitting. (Self contained air-cooled models only)
10. Check the water filter (if applicable) and replace if dirty or restricted
11. Inspect the evaporator water distribution tube to insure even distribution of water
across the face of the evaporator.
12. Clean Remote Condenser if applicable.
Summary of Contents for CIM0320
Page 3: ...ELEVATION SERIES CIM CUBERS TABLE OF CONTENTS ...
Page 36: ...ELEVATION SERIES CIM CUBERS BUTTON FUNCTIONS 33 ...
Page 51: ...ELEVATION SERIES CIM CUBERS EVAPORATOR REPLACEMENT 48 ...
Page 67: ...ELEVATION SERIES WIRING DIAGRAM 64 CIM0530 0636 0836 1126 and 1136 REMOTE COOLED UNITS ...
Page 68: ...ELEVATION SERIES WIRING DIAGRAM 65 CIM0535 0835 and 1135 REMOTE COOLED UNITS ...