ELEVATION SERIES CIM CUBERS
SEQUENCE OF OPERATIONS
18
CONTROL BOARD - INITIATING HARVEST
When the water level in the SUMP drops to close the contacts of the Low Float Switch (LED on Board illu‐
minates) after a 5 second de‐bounce of the switch will signal the start of the Harvest Cycle.
BROWN
BLUE
VIOLET
BLACK
RED
TAN
PINK
YELLOW
= Illuminated LED
WHITE
WHITE
BLUE w/ WHITE
BLUE w/ RED
BLUE
12V DC Switches
Line Voltage
Components
R1
R2
R3
R4
R5
R6