ELEVATION SERIES CIM CUBERS
SEQUENCE OF OPERATIONS
13
CONTROL BOARD - COMPRESSOR START
The Compressor will be energized (R2 on Board illuminated) and the Hot Gas Valve will remain open for 5
more seconds and then de‐energize (R3 on Board off).
BROWN
BLUE
VIOLET
BLACK
RED
TAN
PINK
YELLOW
= Illuminated LED
WHITE
WHITE
BLUE w/ WHITE
BLUE w/ RED
BLUE
12V DC Switches
Line Voltage
Components
R1
R2
R3
R4
R5
R6