Float Housing Assembly
The Float Switch Housing Assembly contains
the High and Low Float Switches along with
the Sump Thermistor. See below for function
of each. See also Sequence of Operation pg. 9.
High and Low Float Switch Operation
The High Float Switch is used to control the water level for ice making, cleaning and sanitizing.
The Float will rise with the water level, opening the contact of the switch and signal the Board to
close the Water Inlet Valve. The LED associated with the High Float switch will be ON when the
contacts of the switch are closed, and will turn OFF when the contacts open. The Low Float
Switch is used to determine when the unit is ready to go into the Harvest Cycle during ice pro‐
duction and when the Sump has been emptied of cleaner or sanitizer during the Cleaning Cycle.
The LED associated with the Low Float Switch operates the same as the LED for the High Float
Switch. The LED will ILLUMINATE when the contact of the float are closed and will turn OFF
when the contacts are open. The Thermistor is used to measure the temperature of the water in
Switch Closed
Position
Switch Opens half
way up Stem.
Switch Closed
Position
High Float
Switch Function
Low Float
Switch Function
Switch Opens half
way up Stem.
High
Float
Low
Float
Thermistor
Summary of Contents for CIM0320
Page 3: ...ELEVATION SERIES CIM CUBERS TABLE OF CONTENTS ...
Page 36: ...ELEVATION SERIES CIM CUBERS BUTTON FUNCTIONS 33 ...
Page 51: ...ELEVATION SERIES CIM CUBERS EVAPORATOR REPLACEMENT 48 ...
Page 67: ...ELEVATION SERIES WIRING DIAGRAM 64 CIM0530 0636 0836 1126 and 1136 REMOTE COOLED UNITS ...
Page 68: ...ELEVATION SERIES WIRING DIAGRAM 65 CIM0535 0835 and 1135 REMOTE COOLED UNITS ...