ELEVATION SERIES CIM CUBER HIGH AND LOW FLOAT SWITCHES AND HOUSING
38
The Bridge Thickness on units under 400# production should be 3/16” while units over 400# pro‐
duction should be 1/8” thick when measured across the middle of the plate. Minor Adjustments
can be made to the bridge thickness by moving the Water Level Adjustment Arm of the Float
Housing up for a thinner bridge or down for a thicker bridge. This adjustment can be made at
any time during the freeze or defrost cycle and the results verified on the following cycle.
Thicker
Bridge
Thinner
Bridge
Splash Curtain
Sump
Summary of Contents for CIM0320
Page 3: ...ELEVATION SERIES CIM CUBERS TABLE OF CONTENTS ...
Page 36: ...ELEVATION SERIES CIM CUBERS BUTTON FUNCTIONS 33 ...
Page 51: ...ELEVATION SERIES CIM CUBERS EVAPORATOR REPLACEMENT 48 ...
Page 67: ...ELEVATION SERIES WIRING DIAGRAM 64 CIM0530 0636 0836 1126 and 1136 REMOTE COOLED UNITS ...
Page 68: ...ELEVATION SERIES WIRING DIAGRAM 65 CIM0535 0835 and 1135 REMOTE COOLED UNITS ...