PROGRAMMING MANUAL

BUNN-O-MATIC CORPORATION

POST OFFICE BOX 3227

SPRINGFIELD, ILLINOIS 62708-3227

PHONE: (217) 529-6601    FAX: (217) 529-6644

41170.0000B   05/12  ©2010 Bunn-O-Matic Corporation

Summary of Contents for AUTOPOD BREWER

Page 1: ...PROGRAMMING MANUAL BUNN O MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD ILLINOIS 62708 3227 PHONE 217 529 6601 FAX 217 529 6644 41170 0000B 05 12 2010 Bunn O Matic Corporation ...

Page 2: ...ions to this warranty or to make additional warranties that are binding on BUNN Accordingly statements by such individuals whether oral or written do not constitute warranties and should not be relied upon If BUNN determines in its sole discretion that the equipment does not conform to the warranty BUNN at its exclusive op tion while the equipment is under warranty shall either 1 provide at no cha...

Page 3: ...Page 3 411701 061308 CONTENTS LOCKOUT SWITCH 4 PROGRAMMING SWITCHES 5 PROGRAMMING 6 ...

Page 4: ...ne of the programming switches are pressed within one minute during programming the display will return to the MAIN SCREEN Always remember to place an empty cup under the sprayhead when operating the brewer during the set up of PULSE BREW CALIBRATE FLOW and testing the brew valve in SERVICE TOOLS TEST OUTPUTS Mounted on main control board This switch can be set to prevent access to the programming...

Page 5: ...and hold the hidden switch Release when the display reads BREW LOCKOUT TheYESorNOshouldbeflashing SelectYEStoprevent brewingifthewatertemperatureisbelowthesetREADY temperature Select NO to permit brewing at any water temperature Whenfinished pressandreleaseDONE Thiswillstepto the next function screen To return to the MAIN SCREEN at any time press and hold the hidden switch BREW LOCKOUT NO DONE YES...

Page 6: ...ber as a password SET LANGUAGE Choose between English or Spanish UNITS METRIC DONE ENG SET LANGUAGE NO YES ENTER ASSET NO YES SET TEMP 200 DONE SET READY 195 DONE UNITS Choose between English Oz F or metric Ml C SET TEMP Adjust tank temperature 185 to 205 F 85 to 96 C SET READY Sets the minimum temperature allowable to start a brew cycle if BrewLockout is enabled Range 2 to 20 F or 2 to 10 C below...

Page 7: ...he SET IDLE TIME has expired 5 50 0 hrs AIR PUMP POWER 1 Weakest 4 Strongest Adjust air pressure for end of brew cycle purge Due to pod variations reduce as needed if splattering occurs BREW COUNTS Retains the total number of brew cycles completed not reset able BREW COUNTS Retains the total number of brew cycles completed reset able CALIBRATE FLOW Thisfunctionallowsyoutoentertheactualflowrateofth...

Page 8: ...ON NEXT OFF WATER PUMP N A WATER PUMP ON NEXT OFF HOT WATER AIR PUMP Activates the air pump motor for the hot water tank HotWaterAir PUMP ON NEXT OFF TANK HEATER Activates the triac relay on the main control board for the brew tank heater TANK HEATER ON NEXT OFF Press the hidden program switch to go back to previous screen Pressing any other membrane switch will give corresponding readout for that...

Page 9: ...Page 9 411701 061308 ...