Summary of Contents for UONP115SS01B

Page 1: ...Collection 30634 Rev_A 30634 Rev_I R egister your new N ugget Ice M achine at u line com and receive a free cleaning kit U LA N U G G ETC LEA N K IT C leaner H ose and Funnel N ugget Ice M achines Pro...

Page 2: ...proud to have the opportunity to ship to you U LINE RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE PRODUCT INFORMATION IMPORTANT Before connecting your new Nugget Ice Machine be sure to carefully follow...

Page 3: ...en you register your product on u line com See complete warranty for details CONTENTS Safety and Warning 4 Environmental Requirements 5 Electrical 5 Water Hookup 6 Drain 12 Door Swing 13 Door Adjustme...

Page 4: ...statement may result in minor or moderate personal injury property or equipment damage Your product may contain R600a Isobutane which is a flammable hydrocarbon To confirm check serial tag inside of...

Page 5: ...r or perform maintenance on the unit until the electricity has been disconnected Never remove the round grounding prong from the plug and never use a two prong grounding adapter Altering cutting or re...

Page 6: ...water line should be looped into 2 coils This will allow the unit to be removed for cleaning and servicing Make certain that the tubing is not pinched or damaged during installation Connect to potable...

Page 7: ...ushing with flat screwdriver 2 Thread water line through back panel hole with bushing 3 Locate water valve inlet and connect to valve 4 Turn on water supply and check for leaks 5 Reinstall back panel...

Page 8: ...on WARNING Connect to potable water supply only CAUTION Review obey and understand the local plumbing codes before you install your unit Connect to the cold water supply The water pressure should be b...

Page 9: ...operation creates some vibration A water supply line contacting an internal component or cabinet wall can cause excessive noise during operation or damage to the line 4 On the back panel break away fi...

Page 10: ...00 ppm or higher and or a hardness of 12 19 gpg can be treated by U Line s in line water filter accessories available at u line com or your local dealer ULALINEFILTER Standard ULALINEFILTERL Large ULA...

Page 11: ...tubing is not pinched or damaged during installation Do not use any plastic water supply line The line is under pressure at all times Plastic may crack or rupture with age and cause damage to your hom...

Page 12: ...T be located directly below the unit Unit has a solid base that will not allow the unit to drain below itself There is a possibility that hose connections may have loosened during shipment Verify all...

Page 13: ...nce is recommended from wall on hinge side to allow the door to open 90 Allow for additional space for any knobs or pulls installed on the integrated panel frame Stainless Steel models that are instal...

Page 14: ...t 2 Loosen do not remove top and bottom hinge screws using a Philips screwdriver on the top and a 1 4 socket on the bottom 3 Align door squarely with cabinet 4 Make sure gasket is firmly in contact wi...

Page 15: ...s on opposite side of cabinet On some models there may be a nut behind one or both screws on either side Install bottom hinge Install two or three screws depending on model Replace nuts if used Instal...

Page 16: ...om top of unit 2 Loosen do not remove top and bottom hinge screws using a Torx T 25 screwdriver 3 Align door squarely with cabinet 4 Make sure gasket is firmly in contact with cabinet all the way arou...

Page 17: ...or both screws on either side Install bottom hinge Install two or three screws depending on model Replace nuts if used Install top hinge and door 1 Remove pivot screw from hinge flip hinge over and i...

Page 18: ...ge cover from top of unit 2 Loosen do not remove top and bottom hinge screws using a Torx T 25 screwdriver on the top and a 1 4 socket on the bottom 3 Align door squarely with cabinet 4 Make sure gask...

Page 19: ...ward exposing the gasket channel 3 Remove the 3 pieces of gasket channel filler and reinstall on the opposite end of door 4 Install gasket into channel beginning at one corner and pressing in firmly 5...

Page 20: ...ver from top of unit 2 Loosen do not remove top and bottom hinge screws using a Torx T 25 screwdriver on the top and a 1 4 socket on the bottom 3 Align door squarely with cabinet 4 Make sure gasket is...

Page 21: ...pletely free from the door surface 2 Continue removing the gasket by grabbing hold and gently pulling outward exposing the gasket channel 3 Remove the 3 pieces of gasket channel filler 4 Take out 2 sc...

Page 22: ...Confirm the unit is level after each adjustment and repeat the previous steps as needed INSTALLATION TIP If the room floor is higher than the floor in the cutout opening adjust the rear legs to achiev...

Page 23: ...and interior light return to normal operation This unit is Star K certified See www star k org for more details 18 23 CONTROL FUNCTION GUIDE FUNCTION COMMAND NOTES ON OFF Press and release Unit will...

Page 24: ...K certified See www star k org for more details 19 24 CONTROL FUNCTION GUIDE FUNCTION COMMAND NOTES ON OFF Press and release Unit will immediately turn On or OFF Adjust ice thickness See Ice section...

Page 25: ...oint for Refrigerator Freezer Enable Sabbath Mode Press and hold for 5 seconds and release The oF oC symbol will flash briefly after 5 seconds Interior light and display will go dark and remain so unt...

Page 26: ...ath Mode Press and release Display and interior light return to normal operation Clean Mode See Cleaning section Showroom Mode Hold and for 5 seconds The F C symbol will flash Display will be lit and...

Page 27: ...e unit is progressing towards the selected temperature Time to reach set point varies based upon ambient temperature temperature of product loaded door openings etc U Line recommends allowing the unit...

Page 28: ...ubes Shake the ice bucket instead During periods of limited use or high ambient temperatures it is common for cubes to fuse together Gently shake the bucket to break apart cubes If not using the ice m...

Page 29: ...ing ice thickness Ice is produced in layers resulting in a clear cube Ice in bin may develop surface frost which disappears when cube is placed in liquid Ice cubes in any given batch will vary so it i...

Page 30: ...ts in the bin the level of ice drops and ice production resumes This ensures a constant supply of fresh ice is always available THINNER BRIDGE THICKER BRIDGE DEEPER DIMPLE SHALLOWER DIMPLE 1 4 TO 1 2...

Page 31: ...er and a nonabrasive cloth Always clean with the grain Always finish with Claire Stainless Steel Polish and Cleaner or comparable product to prevent further problems Using abrasive pads such as Scotch...

Page 32: ...orce ice from the evaporator Damage may result 1 Turn the ice machine off and allow any ice to melt off of the evaporator 2 Remove all ice from the storage bin 3 Remove evaporator cover 4 Remove the s...

Page 33: ...R WATER SUPPLY See WATER HOOKUP section in this guide to find instructions for using the TDS meter that was included with this ice machine Replacement TDS meter may be ordered at uline com Part 80 556...

Page 34: ...isplay a The machine will circulate the solution cleaning and sanitizing the internal components for approximately 20 minutes b While the machine is circulating the cleaning solution use 1 2 of the re...

Page 35: ...e hose and funnel slowly pour 1 5 quarts 48 oz of clean potable water into the ice dispenser tube Air and some water will exit the vent tube d Install new water filter Press and rotate 1 4 turn clockw...

Page 36: ...or improper use maintenance installation service repair acts of God fire flood or other natural disasters The product must be installed operated and maintained in accordance with your product s User G...